Solar Water Heater Controller main technical data:
1 Appearance of controller: see product itself ( dimension: 190mm x140mm x40mm)2 Power supplyAC220V ±10%3 Power consumption< 3W4 Accuracy of temperature measuring ± 2oC5 Range of collector temperature measuring -10 ~200 oC6 Range of tank temperature measuring 0 ~100 oC7 Suitable power of pump 5 pumps possible to be connected, power of each pump < 600W8 Inputs 6 sensors,9 2 piece Pt1000 sensor (≤500oC) for collector (silicon cable≤280oC),10 4 pieces NTC10K, B3950 sensor (≤ 135oC) for tank, (PVC cable ≤105oC),11 Outputs5 relays, for circulation pumps or 3-way electromagnetic valve12 Ambient temperature -10oC ~ 50oC.13 Water proof gradeIP40.14 Socket choice by customer
Main functions4. Controller functions4.1 Access main menu4.2 Access submenu4.3 Main menu THET Timing heating4.4 DT Temperature difference adjusting function4.5 TEMP Temperature main menu4.5.1 EM Emergency collector temperature (emergency switch-off temperature of collector)4.5.2 CMX Maximum limited collector temperature (collector cooling function)4.5.3 CNN Low temperature protection of collector4.5.4 CFR Frost protection of collector4.5.5 REC Tank re-cooling function4.5.6 SMX1 Maximum temperature of tank 14.5.7 SMX2 Maximum temperature of tank 24.5.8 SMX3 Maximum temperature of tank 34.5.9 MAX1 Maximum turnoff temperature (for solid fuel boiler, return heating, heat transferring betweentanks)4.5.10 MIN1 Minimum turn-on temperature (for solid fuel boiler, return heating, heating transferringbetween tanks)4.6 FUN Auxiliary function4.6.1 CIRC Temperature controlled hot water circulation pump4.6.2 nMIN Circuit pump speed adjusting (RPM speed controlling)4.6.3 DTS Standard temperature difference (for circuit pump speed adjusting)4.6.4 RIS Increased rate (for circuit pump speed adjusting)4.6.5 OHQM thermal energy measuring4.6.6 FMAX Flow rate4.6.7 MEDT Type of heat transfer liquid4.6.8 MED% Concentration of antifreeze4.6.9 PRIO Priority logic of tank4.6.10 TRUN Heating loading- time4.6.11 TSTP Heating interval- time4.6.12 DVWG Anti-Legionella function4.6.13 BYPR High temperature by-pass function (tank temperature automatically adjusting)4.7 HND Manual mode4.8 PASS Password setting4.9 RSET Recovery factory setting4.10 ON/OFF button4.11 Holiday function4.12 Manual heating4.13 Temperature query function5. Protection function5.1 Memory protection5.2 Anti-dry heating protection5.3 Screen protection6. Trouble shooting6.1 Trouble protection6.2 Trouble checkingSolar Water Heater Controller